29450 OF-SD

29450-OF/SD auxiliary contact for MCCB provides ON/OFF status indication, fault signaling and interlocking for industrial control systems.
  • Rated Voltage: AC 230V/400V, DC 24V–250V
Share to:

Description

Auxiliary contacts are mechanical contacts within switching electrical appliances (such as circuit breakers and AC contactors). They are widely used in low – voltage power distribution systems, industrial automation, and intelligent control fields, serving to transmit control signals and provide status feedback. Their core functions are as follows

Signal Transmission: By means of the closed or open state of the contacts, they send the operating status signals of the equipment (such as the on – off state of the circuit breaker) to external control systems (such as PLCs and relays).

Interlocking Control: They implement the self – locking and inter – locking logic of electrical equipment, ensuring the safety of the operating sequence (for example, preventing the reverse rotation of a motor).

Remote Monitoring: In conjunction with sensors or communication modules, they provide real – time feedback on the operating status of the equipment (such as fault alarms and power supply switching).

ParameterTypical Value
Rated VoltageAC 230V/400V, DC 24V–250V (in accordance with GB 14048.4/IEC 60947 – 5 – 1)
Rated Current≤0.95A under AC – 15 category, ≤0.15A under DC – 13 category (load – bearing capacity of the control circuit)
Contact TypeCombinations of normally open (NO) and normally closed (NC), with support for extended configurations (such as 2NO + 2NC)

SDE(Signal for Fault Trip)

Function and Installation

DE (Signal for Fault Trip): Only indicates fault tripping (such as overload, short – circuit, leakage), and does not respond to manual testing or shunt tripping.

Testing Method

Install the SDE adapter and contacts at the circuit breaker’s tripping position; Open the circuit breaker → Close the circuit breaker → Trigger the orange Trip button or push the Vigi rod (simulating a fault); Use a multimeter to detect the state of the SDE contacts: When tripping occurs, the contacts should reverse (switch between normally open and normally closed); If there is no change, the adapter may be faulty.

Differences from SD/OF Contacts SD contacts: Respond to all tripping situations (including faults and manual operations); OF contacts: Only indicate the on/off state (tripping is regarded as off).

FAQ

What is the Rated Voltage for

For 29450 OF-SD, the listed Rated Voltage is AC 230V/400V, DC 24V–250V. Confirm the exact configuration against your project requirements before ordering.

ODM & OEM Service

Our technical team can provide customized R&D and design services based on your needs. We will respond to your customization requests within 16 hours.

Frequently Asked Questions

Do you support custom production with our brand logo?

Yes, we provide OEM/ODM/OBM/OPM services. Please contact us for MOQ, design and other details.

We make high-quality products. All items are strictly tested, with full raw material control and no cutting corners.
We have long-term stable logistics partners for safe and efficient delivery. You can also appoint your own freight forwarder.
We do not attend exhibitions, which effectively protects our customers’ product supply channels.
Absolutely, many of our customers do this.
Standard production lead time is 3-5 weeks, expedited processing is available.
Yes, we are happy to give preferential prices for bulk purchases.

Request For Quote

We will reply to your inquiry within 16 hours.
+86-13216097216 Phone helge@wzsmo.com E-mail Chat on WhatsApp WhatsApp