MN 100A-1600A

MN under voltage trip device (100–1600A) disconnects MCCB when voltage drops below threshold, protecting motors and PLC systems from low-voltage damage.
  • CONTROL VOLTAGE: AC 220V-240V / DC 24V(UC)
  • INRUSH POWER: MX200VA / MN: 10VA
  • OPERATING THRESHOLD: MX: 70%-110% Uc / MN: 35%-70% Uc
  • STANDARD: IEC 60947-2, CE
Share to:

Description

Under Voltage Trip Device Function

The under voltage trip device is used to automatically disconnect the circuit breaker when the supply voltage drops below a set threshold, preventing equipment from being damaged due to operating at low voltages.

Working Principle

When the voltage drops to a set value (such as 70% – 35% of the rated voltage), the coil of the trip device loses its magnetism, triggering the circuit breaker to trip.

Application Scenarios

  • Protecting sensitive equipment (such as motors, PLCs, frequency converters) from the impact of voltage fluctuations.
  • Places with high requirements for power system stability (such as data centers, hospitals).
  • Cooperating with automatic reclosing to achieve automatic restart after fault recovery.

Technical Parameters

  • Rated voltage: Consistent with the rated voltage of the circuit breaker (e.g., AC 230V/400V).
  • Action threshold: Adjustable range (e.g., 50% – 90% Un).
  • Recovery method: Automatic recovery (delayed closing after voltage recovery) or manual reset.
  • Installation method: Connect to the circuit breaker body through a plug – in or screw – fixed type.

FAQ

What is the CONTROL VOLTAGE for

For MN 100A-1600A, the listed CONTROL VOLTAGE is AC 220V-240V / DC 24V(UC). Confirm the exact configuration against your project requirements before ordering.

What is the INRUSH POWER for

For MN 100A-1600A, the listed INRUSH POWER is MX200VA / MN: 10VA. Confirm the exact configuration against your project requirements before ordering.

What is the OPERATING THRESHOLD for

For MN 100A-1600A, the listed OPERATING THRESHOLD is MX: 70%-110% Uc / MN: 35%-70% Uc. Confirm the exact configuration against your project requirements before ordering.

What is the STANDARD for

For MN 100A-1600A, the listed STANDARD is IEC 60947-2, CE. Confirm the exact configuration against your project requirements before ordering.

ODM & OEM Service

Our technical team can provide customized R&D and design services based on your needs. We will respond to your customization requests within 16 hours.

Frequently Asked Questions

Do you support custom production with our brand logo?

Yes, we provide OEM/ODM/OBM/OPM services. Please contact us for MOQ, design and other details.

We make high-quality products. All items are strictly tested, with full raw material control and no cutting corners.
We have long-term stable logistics partners for safe and efficient delivery. You can also appoint your own freight forwarder.
We do not attend exhibitions, which effectively protects our customers’ product supply channels.
Absolutely, many of our customers do this.
Standard production lead time is 3-5 weeks, expedited processing is available.
Yes, we are happy to give preferential prices for bulk purchases.

Request For Quote

We will reply to your inquiry within 16 hours.
+86-13216097216 Phone helge@wzsmo.com E-mail Chat on WhatsApp WhatsApp